lucidgugl.blogg.se

Hantek 6022be software windows 10
Hantek 6022be software windows 10










hantek 6022be software windows 10
  1. #HANTEK 6022BE SOFTWARE WINDOWS 10 DRIVERS#
  2. #HANTEK 6022BE SOFTWARE WINDOWS 10 FULL#

While the 6022BL is plugged into a USB port the PC crashes.The 6022BL has the button pressed in at the rear of the instrument.If I remove the 6022 from the USB the system stops crashing but from now on there is no way to remove the faulty driver as if I plug the PC Oscilloscope in to the USBWindows 10 crashes immediately.Thankfully I do a complete System backup before trying to reinstall Hantek driver.Įven though I am installing the English drivers Windows asks whether I trust this software.Image is attached.ĭo you have signed drivers and something that will work and not crash Windows 1064bit.? Stop Code: SYSTEM THREAD_EXCEPTION NOT HANDLED The driver installed and for a brief second I saw the Windows message saying that the device was correctly installed.Ībout 1-2 seconds later the Windows blue screen appears with the message: Hantek 6022be oscilloscope software update# I am at the stage of replacing the PC Oscilloscope with another brand as this is totally frustrating.Are you able to help? Hantek 6022be oscilloscope software drivers# Go to this path (C:\Windows\System32\drivers) and find the file (Hantek6022BLAMD641.SYS/Hantek6022BLAMD642.SYS). When enabled, every trace is saved in data.csv (or file of user’s choice), unless that file already exists.īasicScope 1.2 source for Visual Studio 2010 Express Data Acquisition Mode added for interface with 3rd party programs.If the problem still exists after the update, please let me know.BasicScope 1.3 source for Visual Studio 2010 Express oem files (which may contain these"USB\VID_04B4&PID_602A.DeviceDesc%=Hantek6022BL1.Dev, USB\VID_04B4&PID_602A Go to this path (C:\Windows\INF) and find the new. Font installation changed again to handle a corner case in Windows XP.No changes to actual BasicScope program.īasicScope 1.1 source for Visual Studio 2010 Express Better font installation should fix incorrectly-drawn markers on Windows 7.Window state (Maximized, Normal, Minimized) now saved.īasicScope 1.0 source for Visual Studio 2010 Express.Added time indices and trigger info to CSV output file.Larger markers, and smaller capture radius for dragging markers.

hantek 6022be software windows 10

(Version 0.19 was a private build to test 6022BL compatibility.) Program automatically requests to run as Administrator, so that settings can be saved.Otherwise identical to previous build.īasicScope 0.17 source for Visual Studio 2010 Express Icons drawn for the following buttons: Markers, Park Markers, Extra Info Line, Unzoom, Software Trigger.(Version 0.16 was a private build to test 6022BL compatibility.)īasicScope 0.15 source for Visual Studio 2010 Express

hantek 6022be software windows 10

  • On first usage after install, voltage on both channels was set to a bad value until the sliders were moved – fixed.
  • BasicScope now is packaged in an installer.
  • Unzoom now restores original voltage settings of trace.īasicScope 0.14 binary for Windows XP and laterīasicScope 0.14 source for Visual Studio 2010 Express.
  • #HANTEK 6022BE SOFTWARE WINDOWS 10 FULL#

    Hardware trigger won’t work above about 80% of full scale.Starting with version 0.14, this can be worked around by enabling software triggering. It is possible to set a trigger level beyond full scale of the scope.Hantek 6022be oscilloscope software full#įor example, if the scope is ±5 volts full scale, the user could set a trigger level of 6 volts, causing the scope to never trigger Starting with version 0.14, there is a warning posted in the tooltip for the trigger level. Added more info to saved trace for bug reporting purposesīasicScope 0.13 binary for Windows XP (32-bit)īasicScope 0.13 source for Visual Studio 2010 ExpressĮnhanced (best guess) documentation for HTMarch_dllĮnhanced (best guess) documentation for HTDisplayDll. I have to admit, I never tried the program on Windows 10, but if the Hantek software works, then I think there’s hope for BasicScope. This may require a bit of detective work. The first, easy thing to try, is once the Hantek software is working, try reinstalling BasicScope. Hantek 6022be oscilloscope software software#.Hantek 6022be oscilloscope software full#.Hantek 6022be oscilloscope software update#.Hantek 6022be oscilloscope software drivers#.Hantek 6022be oscilloscope software install#.












    Hantek 6022be software windows 10